September 7

2000W Solar on Grid Tie Inverter Limit for PV Panels Battery Home SUN 2000G TIL

2000W Solar on Grid Tie Inverter Limit for PV Panels Battery Home SUN 2000G TIL
2000W Solar on Grid Tie Inverter Limit for PV Panels Battery Home SUN 2000G TIL
2000W Solar on Grid Tie Inverter Limit for PV Panels Battery Home SUN 2000G TIL
2000W Solar on Grid Tie Inverter Limit for PV Panels Battery Home SUN 2000G TIL
2000W Solar on Grid Tie Inverter Limit for PV Panels Battery Home SUN 2000G TIL

2000W Solar on Grid Tie Inverter Limit for PV Panels Battery Home SUN 2000G TIL
2000W Solar on Grid Tie Inverter with Power Limiter DC 45-90V PV system. 2nd Generation 2000w Solar Power Grid Tie Inverter. AC 220V 230V 240V (auto selected). Item Details: 2000w Solar Power Grid Tie Inverter. With Limiter / Sensor Battery Discharge Power Mode. Why we produced the GRID TIE INVERTER WITH LIMITER? It is in response to the overwhelming clamor from our customers for a product that can control the amount of power that the grid tie inverters (GTI) can generate so that the amount of excess power produced by the solar panels are reduced to insignificant levels, if not eliminated — because in some countries, the producer pays for the excess power it gives to the distribution grid. This is because the electric power meters (the one provided by the electricity provider in the area) are not aware of the direction of power flow. In other words it only adds even if power is exported to the grid, thus, the consumers will be charged for power even if it is given to the grid, and this is the problem This is the 2nd generation grid tie inverter with limiter. But in case customer install inverter far away from the main circuit breaker, we also enable the 2nd GTIL work with stand-alone limiter, we call this-external limiter. For sure, the inverter can work under normal Grid tie-no limit mode, just set on the nice LCD and save your setting. New upgraded firmware enable battery or solar limiter current and power model. User can set the maximum output power of inverter , this can make the inverter work at cooler contition as user want and extend the lifespan of the inverter. User can set kick in/off voltage of the inverter which can flexible using with battery bank depend on users mind and can prevent battery bank from over discharged. #1 Solar on grid tie inverter. Input DC Voltage Range. Peak power tracking voltage. AC Output Voltage Range. Dimensions (W x H x D). Description: a: DC input , for solar panels connection b: Connector for external limiter c: Connector for internal limiter d: AC output , use AC cable to connect to home grid Sensor Clamp. How to use the Inverter? Standard Grid Tie Inverter Model(one unit inverter). More than 1 unit inverters stackable. The Grid Tie inverter converts DC power produced by Solar Panels to AC, connects to the grid and feed all of the power available from the panels to the AC load. All excess power that is not needed by the load is then exported to the Grid. If the Grid fails, then the Grid Tie Inverter will turn off. When the Grid comes back on line. The Grid Tie Inverter will again supply power to the load and any excess power is exported to the Grid again. If the Solar Panel is producing less power and the GTI cannot deliver all the power needed by the load, then power will be supplemented by the Grid. Power Meters (Except smart meter) are not aware of the direction of Power flow. The user then pays for the power exported and delivered by the Grid. Using Grid Tie Inverter With Limiter Model. 2.1 The Grid Tie Inverter with Limiter delivers only the power needed by the load and prevents delivering excess power hence avoids excess power in going back to the Grid. 2.2 The heart of the Grid Tie Inverter with Limiter is the Limiter Module (LM). The LM continuously sampled the power needed by the load through the current sensor connected after the Main Circuit Breaker. The LM then will process the signal. It then sends signal to Grid Tie Inverter how much power to deliver to the load in real time. 2.3 The user, after installing and connecting the GTIL correctly, need not do anything and the unit will do its work automatically. Installation of GTIL With Internal Limiter. 3.1 This installation is not require an additional limiter module, Installation is much easier. Clamp the current sensor cable to the hot wire to measure the current, the internal limiter will auto detect the load power and control the inverter output power, excess power will be well controlled. 3.2 External protective device including dc and ac SPD(Surge protection device), dc and ac breaker, etc is recommended to installed in the system. Limiter Setting on the LCD of the inverter: The GTIL include three working mode:Work as normal GTI without power limitation. Work under Internal limiter mode and Work under External limiter mode, Pls make your setting on the LCD and save it, details setting operation, pls read the GTI manual. 5 Battery Discharge Power Mode New upgraded firmware enable battery or solar limiter current and power model. 6 Limiter Module Specification. Clamp sensor- Max 100A. Clamp sensor signal- 5v AC max mA. DC signal Cable- 5v DC, max mA. Fengefengefenge If the distance of meter and inverter is too long , you will need the External Limiter. Note: The external limiter is not included in package. Wifi Port for MPPT 1000W/2000W NEW SUN Solar Grid Tie Inverter. NOTE : It will be built-in side the inverter. We are not responsible for undeliverable address. Pleas message us if recipient address changes needed before we fulfill the order. Sorry, no local pickups available. No need return the original one for low-valued items. All return products should be in original package with all accessories included. We stand behind our products so you are always covered! The item “2000W Solar on Grid Tie Inverter Limit for PV Panels Battery Home SUN 2000G TIL” is in sale since Thursday, August 30, 2018. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “chargerangel” and is located in Pasadena, Texas. This item can be shipped to United States.
  • Modified Item: No
  • Custom Bundle: No
  • MPN: Does Not Apply
  • Brand: iMeshbean
  • Non-Domestic Product: No

2000W Solar on Grid Tie Inverter Limit for PV Panels Battery Home SUN 2000G TIL
Category: 2000w | Comments Off
September 7

Enphase M215 Micro Inverter Grid Tie Microinverter with MC4 Male Female Connector

Enphase M215 Micro Inverter Grid Tie Microinverter with MC4 Male Female Connector
Enphase M215 Micro Inverter Grid Tie Microinverter with MC4 Male Female Connector

Enphase M215 Micro Inverter Grid Tie Microinverter with MC4 Male Female Connector
Enphase On-Grid Microinverter M215 with MC4 Connectors. Minimizes impact of shading, dust, and debris. No single point of system failure. No GEC needed for microinverter. No DC design or string calculation requried. Easy installation with Engage Cable. The Enphase M215 Microinverter with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the advanced M215, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. Please Note: Microinverters are not Rule 21 Complaint and cannot be installed in California. We offer complete residential and commercial solar kits for both on-grid and off-grid applications, including inverters, railing, and other system components. Thinking about purchasing our products in bulk? We offer discounts for bulk orders. Recommended input power (STC): 190 – 270W. Maximum input DC voltage: 48V. Peak power tracking voltage: 27 V – 39 V. Operating range: 16 V – 48V. Min/Max start voltage: 22V / 48V. Max DC short circuit current: 15A. Peak output power: 225W. Rated (continuous) output power: 215W. Nominal output current: (A rms at nominal duration) 208 VAC: 1.03 A 240 VAC: 0.9 A. Nominal voltage/range: 208 V / 183-229 V 240 V / 211-264 V. Nominal frequency/range: 60.0 / 57-61 Hz. Extended frequency range: 57-62.5 Hz. Power factor: >0.95. Maximum output fault current: 850 mA rms for 6 cycles. Maximum units per 20 A branch circuit: 208 VAC: 25 (three phase) 240 VAC: 17 (single phase). CEC weighted efficiency: 96.5%. Peak inverter efficiency: 96.5%. Static MPPT efficiency (weighted, reference EN50530): 99.4 %. Night time power consumption: 65 mW max. Ambient temperature range: -40ºC to +65ºC. Cooling: Natural convection – No fans. Weight: 1.6 kg (3.4 lbs). Dimensions (WxHxD): 171 mm x 173 mm x 30 mm (without mounting bracket). Connector type: M250-60-2LL-S22: MC4 M250-60-2LL-S25: Amphenol H4. Compatibility: Compatible with 60-cell PV modules. Monitoring: Enlighten Manager and MyEnlighten monitoring options. Compliance: UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01. Integrated ground: The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Ground fault protection (GFP) is integrated into the microinverter. Please note that we won’t be able to process any order with PO Box address for any size of solar panel. Anything outside of this policy requires special authorization. Other Items You Might Be Interested In. Phoenix All-in-one Solar Generator. Deep Cycle AGM Battery. The item “Enphase M215 Micro Inverter Grid Tie Microinverter with MC4 Male Female Connector” is in sale since Tuesday, March 5, 2013. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “renogy_solar” and is located in Ontario, California. This item can be shipped to United States.
  • Model: Micro Inverter M215 MC4 Connector
  • Modified Item: No
  • Custom Bundle: No
  • Type: Micro Inverter
  • MPN: ENP-OS-INVT-M215
  • Brand: Enphase
  • Non-Domestic Product: No

Enphase M215 Micro Inverter Grid Tie Microinverter with MC4 Male Female Connector
Category: enphase | Comments Off