This is a new SMA DC Disconnect. This is for an order of only one DC Disconnect. Inverter is NOT included. Please see specs below. DC_Disc-IUS082311 1 / 4 Additional Information for Installation SMA DC-Disconnect Accessories for PV Inverters Version: 1.1 Mat. DB-DC-DISCON Please check the Installation Guide delivered with your Sunny Boy. If the Installation Guide version is earlier than 2.1 (for example 1.2 or 1.3), then please read this information carefully and follow the instructions below. If your Sunny Boy Installation Guide has the version 2.1 you may disregard this additional information. The SMA DC-Disconnect is a DC circuit breaker disconnecting the PV generator from the inverter. The SMA DC-Disconnect is NOT an AC circuit breaker. This Additional Information describes the wiring of the DC-Disconnect. This instruction does NOT replace the Sunny Boy Installation Guide. Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. The Installation Guide describes how to connect the DCDisconnect and provides information on the torque of the cable connection. AC Wiring with SMA DC-Disconnect The Sunny Boy 3000US and 4000US are suitable for the connection to a 208 V and 240 V grid. The Sunny Boy 5000US, 6000US and 7000US are suitable for the connection to a 208 V, 240 V and 277 V grid. L1 Connect the black L1 (AC line 1 or UNGROUNDED) wire to the terminal labeled L1 in the SMA DC-Disconnect L2 Connect the red L2 (AC line 2) to the terminal labeled L2 in the SMA DC-Disconnect. Only for 277 V: L2 terminal not used! N Connect the white N (AC line N) wire to the terminal labeled N in the SMA DCDisconnect. PE Connect the green-yellow AC equipment- ground wire to the PE terminal labeled in the SMA DC-Disconnect. SMA Solar Technology AG DC_Disc-IUS082311 2 / 4 Additional Information for Installation DC Ground Wiring With SMA DC-Disconnect Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. DC Wiring With SMA DC-Disconnect Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. A Connect the grounding electrode conductor with the grounding electrode. B Connect the PV generator grounding to the grounding electrode. Negative Grounding Connect the positive DC wires to the terminal labeled PV UNGROUNDED in the SMA DC-Disconnect. Connect the negative DC wires to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Positive Grounding Connect the negative DC wires to the terminal labeled PV UNGROUNDED in the SMA DC-Disconnect. Connect the positive DC wires to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. SMA Solar Technology AG DC_Disc-IUS082311 3 / 4 Additional Information for Installation DC Wiring With Additional DC Distribution When combining strings outside of the SMA DC-Disconnect, and when the combined input of a single source circuit is greater than 15 A, use the terminal labeled COMBINED for the ungrounded conductor. DO NOT use the terminals 1 – 4 labeled UNGROUNDED in this case. For connecting the DC wires to the Sunny Boy, see Installation Guide of the Sunny Boy. Torque Values and Wire Sizes SMA DC-Disconnect Additional DC Source Circuit Note: This circuit will no longer be fused so additional DC source circuit fusing may be required in order to meet UL and NEC. Negative Grounding Connect the positive DC wire to the terminal labeled COMBINED in the SMA DC-Disconnect. Connect the negative DC wire to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Positive Grounding Connect the negative DC wire to the terminal labeled COMBINED in the SMA DC-Disconnect. Connect the positive DC wire to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Wire Size AC & DC Terminal Blocks 15 1.7 6 – 10 AWG Combined Terminal Block Spring Terminal Spring Terminal 6 – 10 AWG Grounding Electrode Conductor Block 15 1.7 6 – 10 AWG SMA Solar Technology AG DC_Disc-IUS082311 4 / 4 Additional Information for Installation AC Wiring in the Sunny Boy Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. L1 Connect the black L1 (AC line 1 or UNGROUNDED) wire of the SMA DCDisconnect to the terminal labeled L1 in the Sunny Boy. L2 Connect the red L2 (AC line 2) wire of the SMA DC-Disconnect to the terminal labeled L2 in the Sunny Boy. N Connect the white N (AC line N) wire of the SMA DC-Disconnect to the terminal labeled N in the Sunny Boy. PE Connect the green-yellow AC equipment-ground wire of the SMA DCDisconnect to the PE terminal labeled in the Sunny Boy. WE WILL USE ADDRESS ON FILE AT THE TIME OF CHECKOUT AND WILL NOT ACCEPT RESPONSIBILITY FOR ADDRESSES THAT ARE INCORRECT OR UNDELIVERABLE. PLEASE PAY FOR ITEMS WITHIN 7 DAYS OF ITEM CLOSING DATE. The item “DC Combiner Box and Disconnect for SMA Grid Tie Inverter NEW in Box” is in sale since Monday, January 02, 2017. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “dualsportgirl” and is located in Nevada City, California. This item can be shipped to United States, to Canada, DK, RO, SK, BG, CZ, FI, HU, LV, LT, EE, to Australia, GR, SI, KR, ID, to Taiwan, ZA, TH, to France, to Hong Kong, to Germany, to Austria, to Mexico, PH, SG, HR, MY, BR, CL, CO, CR, DO, PA, TT, GT, SV, HN, JM.
- Brand: SMA
- Country/Region of Manufacture: Germany