August 11

5000W Grid Tie Inverter 230VAC 50Hz Schneider Electric Inverter

5000W Grid Tie Inverter 230VAC 50Hz Schneider Electric Inverter

5000W Grid Tie Inverter 230VAC 50Hz Schneider Electric Inverter
Efficiency > 94.5 % European. > 96 % maximum. Number of MPPT : 3. Photovoltaic power : 5400 Wp. Voltage range MPP input : 200…700 V DC. Input voltage : 150 V DC for feed-in. 750 V DC for open circuit. Maximum input current : 3 x 8.5 A DC. AC output power Output nominal : 4600 W. Output maximum : 5100 W. Output voltage :230 V AC 50 Hz. Maximum output current :25 A. Display type Backlit LCD. Power consumption 9 W. Standby consumption < 0.5 W. Connector MC4 (1 pair per MPPT) DC. Communication port SunEzy RS485. IP degree of protection IP65. Product weight 27 kg. Ambient air temperature for operation -20...55 °C. Relative humidity 0...95 %. Noise level < 35 dB. The item "5000W Grid Tie Inverter 230VAC 50Hz Schneider Electric Inverter" is in sale since Wednesday, May 17, 2017. This item is in the category "Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters". The seller is "sunelec_miami" and is located in Opa-Locka, Florida. This item can be shipped worldwide.
  • Brand: Schneider Electric
  • Model: PVSNV1600E
  • MPN: PVSNV1600E
  • Type: Grid Tie Inverter

5000W Grid Tie Inverter 230VAC 50Hz Schneider Electric Inverter
Category: 5000w | Comments Off
May 22

SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Inverter & Disconnect

SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Inverter & Disconnect

SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Inverter & Disconnect
SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Off-Grid Inverter & Disconnect. This inverter was manufactured in 04/13 and the disconnect was in 06/13. This was in operation when I removed it from the garage of a house to install a newer style system (Enphase Microinverters). It comes with mounting bracket. It is used in great condition. My pictures show it well. There is some paint on the inverter from painting around it but does not effect the performance. Take a look at our other listing, we might have something to interest you! All sales are final. If you have a problem please let me know so we can work it out. We are not responsible for any mishap that may occur in the install of this product. This needs to be installed by a professional Electrician. View My Other Items For Sale. Get Images that Make Supersized Seem Small. Auctiva’s Listing Templates improve your auctions in minutes. Attention Sellers – Get Templates Image Hosting, Scheduling at Auctiva. Track Page Views With. Auctiva’s FREE Counter. The item “SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Inverter & Disconnect” is in sale since Sunday, May 21, 2017. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “tobdyl” and is located in Lincoln, California. This item can be shipped to United States.
SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Inverter & Disconnect
Category: sunny | Comments Off
April 21

SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Off-Grid Inverter & Disconnect

SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Off-Grid Inverter & Disconnect

SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Off-Grid Inverter & Disconnect
SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Off-Grid Inverter & Disconnect. This inverter was manufactured in 04/13 and the disconnect was in 06/13. This was in operation when I removed it from the garage of a house to install a newer style system (Enphase Microinverters). It comes with mounting bracket. It is used in great condition. My pictures show it well. There is some paint on the inverter from painting around it but does not effect the performance. Take a look at our other listing, we might have something to interest you! If you have a problem please let me know so we can work it out. We are not responsible for any mishap that may occur in the install of this product. This needs to be installed by a professional Electrician. View My Other Items For Sale. Get Images that Make Supersized Seem Small. Auctiva’s Listing Templates improve your auctions in minutes. Attention Sellers – Get Templates Image Hosting, Scheduling at Auctiva. Track Page Views With. Auctiva’s FREE Counter. The item “SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Off-Grid Inverter & Disconnect” is in sale since Thursday, April 20, 2017. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “tobdyl” and is located in Lincoln, California. This item can be shipped to United States.
SMA Sunny Boy SB 3000-US Solar Electric Grid-Tie Off-Grid Inverter & Disconnect
Category: sunny | Comments Off
March 28

4 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter

4 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
4 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter

4 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
New, unopened, factory sealed box. You will receive 4 count SMA DC Disconnect/Combiner Boxes in this offer. DC_Disc-IUS082311 1 / 4 Additional Information for Installation SMA DC-Disconnect Accessories for PV Inverters Version: 1.1 Mat. DB-DC-DISCON Please check the Installation Guide delivered with your Sunny Boy. If the Installation Guide version is earlier than 2.1 (for example 1.2 or 1.3), then please read this information carefully and follow the instructions below. If your Sunny Boy Installation Guide has the version 2.1 you may disregard this additional information. The SMA DC-Disconnect is a DC circuit breaker disconnecting the PV generator from the inverter. The SMA DC-Disconnect is NOT an AC circuit breaker. This Additional Information describes the wiring of the DC-Disconnect. This instruction does NOT replace the Sunny Boy Installation Guide. Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. The Installation Guide describes how to connect the DCDisconnect and provides information on the torque of the cable connection. AC Wiring with SMA DC-Disconnect The Sunny Boy 3000US and 4000US are suitable for the connection to a 208 V and 240 V grid. The Sunny Boy 5000US, 6000US and 7000US are suitable for the connection to a 208 V, 240 V and 277 V grid. L1 Connect the black L1 (AC line 1 or UNGROUNDED) wire to the terminal labeled L1 in the SMA DC-Disconnect L2 Connect the red L2 (AC line 2) to the terminal labeled L2 in the SMA DC-Disconnect. Only for 277 V: L2 terminal not used! N Connect the white N (AC line N) wire to the terminal labeled N in the SMA DCDisconnect. PE Connect the green-yellow AC equipment- ground wire to the PE terminal labeled in the SMA DC-Disconnect. SMA Solar Technology AG DC_Disc-IUS082311 2 / 4 Additional Information for Installation DC Ground Wiring With SMA DC-Disconnect Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. DC Wiring With SMA DC-Disconnect Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. A Connect the grounding electrode conductor with the grounding electrode. B Connect the PV generator grounding to the grounding electrode. Negative Grounding Connect the positive DC wires to the terminal labeled PV UNGROUNDED in the SMA DC-Disconnect. Connect the negative DC wires to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Positive Grounding Connect the negative DC wires to the terminal labeled PV UNGROUNDED in the SMA DC-Disconnect. Connect the positive DC wires to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. SMA Solar Technology AG DC_Disc-IUS082311 3 / 4 Additional Information for Installation DC Wiring With Additional DC Distribution When combining strings outside of the SMA DC-Disconnect, and when the combined input of a single source circuit is greater than 15 A, use the terminal labeled COMBINED for the ungrounded conductor. DO NOT use the terminals 1 – 4 labeled UNGROUNDED in this case. For connecting the DC wires to the Sunny Boy, see Installation Guide of the Sunny Boy. Torque Values and Wire Sizes SMA DC-Disconnect Additional DC Source Circuit Note: This circuit will no longer be fused so additional DC source circuit fusing may be required in order to meet UL and NEC. Negative Grounding Connect the positive DC wire to the terminal labeled COMBINED in the SMA DC-Disconnect. Connect the negative DC wire to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Positive Grounding Connect the negative DC wire to the terminal labeled COMBINED in the SMA DC-Disconnect. Connect the positive DC wire to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Wire Size AC & DC Terminal Blocks 15 1.7 6 – 10 AWG Combined Terminal Block Spring Terminal Spring Terminal 6 – 10 AWG Grounding Electrode Conductor Block 15 1.7 6 – 10 AWG SMA Solar Technology AG DC_Disc-IUS082311 4 / 4 Additional Information for Installation AC Wiring in the Sunny Boy Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. L1 Connect the black L1 (AC line 1 or UNGROUNDED) wire of the SMA DCDisconnect to the terminal labeled L1 in the Sunny Boy. L2 Connect the red L2 (AC line 2) wire of the SMA DC-Disconnect to the terminal labeled L2 in the Sunny Boy. N Connect the white N (AC line N) wire of the SMA DC-Disconnect to the terminal labeled N in the Sunny Boy. PE Connect the green-yellow AC equipment-ground wire of the SMA DCDisconnect to the PE terminal labeled in the Sunny Boy. WE WILL USE ADDRESS ON FILE AT THE TIME OF CHECKOUT AND WILL NOT ACCEPT RESPONSIBILITY FOR ADDRESSES THAT ARE INCORRECT OR UNDELIVERABLE. PLEASE PAY FOR ITEMS WITHIN 7 DAYS OF ITEM CLOSING DATE. We are located 30 minutes from. Pay with Pay Pal. The item “4 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter” is in sale since Monday, March 27, 2017. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “dualsportgirl” and is located in Nevada City, California. This item can be shipped to United States.
  • Brand: SMA
  • MPN: Does Not Apply
  • Country/Region of Manufacture: Germany

4 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
Category: count | Comments Off
March 27

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
New, unopened, factory sealed box. You will receive 8 count SMA DC Disconnect/Combiner Boxes in this offer. DC_Disc-IUS082311 1 / 4 Additional Information for Installation SMA DC-Disconnect Accessories for PV Inverters Version: 1.1 Mat. DB-DC-DISCON Please check the Installation Guide delivered with your Sunny Boy. If the Installation Guide version is earlier than 2.1 (for example 1.2 or 1.3), then please read this information carefully and follow the instructions below. If your Sunny Boy Installation Guide has the version 2.1 you may disregard this additional information. The SMA DC-Disconnect is a DC circuit breaker disconnecting the PV generator from the inverter. The SMA DC-Disconnect is NOT an AC circuit breaker. This Additional Information describes the wiring of the DC-Disconnect. This instruction does NOT replace the Sunny Boy Installation Guide. Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. The Installation Guide describes how to connect the DCDisconnect and provides information on the torque of the cable connection. AC Wiring with SMA DC-Disconnect The Sunny Boy 3000US and 4000US are suitable for the connection to a 208 V and 240 V grid. The Sunny Boy 5000US, 6000US and 7000US are suitable for the connection to a 208 V, 240 V and 277 V grid. L1 Connect the black L1 (AC line 1 or UNGROUNDED) wire to the terminal labeled L1 in the SMA DC-Disconnect L2 Connect the red L2 (AC line 2) to the terminal labeled L2 in the SMA DC-Disconnect. Only for 277 V: L2 terminal not used! N Connect the white N (AC line N) wire to the terminal labeled N in the SMA DCDisconnect. PE Connect the green-yellow AC equipment- ground wire to the PE terminal labeled in the SMA DC-Disconnect. SMA Solar Technology AG DC_Disc-IUS082311 2 / 4 Additional Information for Installation DC Ground Wiring With SMA DC-Disconnect Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. DC Wiring With SMA DC-Disconnect Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. A Connect the grounding electrode conductor with the grounding electrode. B Connect the PV generator grounding to the grounding electrode. Negative Grounding Connect the positive DC wires to the terminal labeled PV UNGROUNDED in the SMA DC-Disconnect. Connect the negative DC wires to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Positive Grounding Connect the negative DC wires to the terminal labeled PV UNGROUNDED in the SMA DC-Disconnect. Connect the positive DC wires to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. SMA Solar Technology AG DC_Disc-IUS082311 3 / 4 Additional Information for Installation DC Wiring With Additional DC Distribution When combining strings outside of the SMA DC-Disconnect, and when the combined input of a single source circuit is greater than 15 A, use the terminal labeled COMBINED for the ungrounded conductor. DO NOT use the terminals 1 – 4 labeled UNGROUNDED in this case. For connecting the DC wires to the Sunny Boy, see Installation Guide of the Sunny Boy. Torque Values and Wire Sizes SMA DC-Disconnect Additional DC Source Circuit Note: This circuit will no longer be fused so additional DC source circuit fusing may be required in order to meet UL and NEC. Negative Grounding Connect the positive DC wire to the terminal labeled COMBINED in the SMA DC-Disconnect. Connect the negative DC wire to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Positive Grounding Connect the negative DC wire to the terminal labeled COMBINED in the SMA DC-Disconnect. Connect the positive DC wire to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Wire Size AC & DC Terminal Blocks 15 1.7 6 – 10 AWG Combined Terminal Block Spring Terminal Spring Terminal 6 – 10 AWG Grounding Electrode Conductor Block 15 1.7 6 – 10 AWG SMA Solar Technology AG DC_Disc-IUS082311 4 / 4 Additional Information for Installation AC Wiring in the Sunny Boy Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. L1 Connect the black L1 (AC line 1 or UNGROUNDED) wire of the SMA DCDisconnect to the terminal labeled L1 in the Sunny Boy. L2 Connect the red L2 (AC line 2) wire of the SMA DC-Disconnect to the terminal labeled L2 in the Sunny Boy. N Connect the white N (AC line N) wire of the SMA DC-Disconnect to the terminal labeled N in the Sunny Boy. PE Connect the green-yellow AC equipment-ground wire of the SMA DCDisconnect to the PE terminal labeled in the Sunny Boy. WE WILL USE ADDRESS ON FILE AT THE TIME OF CHECKOUT AND WILL NOT ACCEPT RESPONSIBILITY FOR ADDRESSES THAT ARE INCORRECT OR UNDELIVERABLE. PLEASE PAY FOR ITEMS WITHIN 7 DAYS OF ITEM CLOSING DATE. We are located 30 minutes from. Pay with Pay Pal. The item “8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter” is in sale since Monday, March 27, 2017. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “dualsportgirl” and is located in Nevada City, California. This item can be shipped to United States.
  • Brand: SMA
  • MPN: Does Not Apply
  • Country/Region of Manufacture: Germany

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
Category: count | Comments Off
February 23

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
New, unopened, factory sealed box. You will receive 8 count SMA DC Disconnect/Combiner Boxes in this offer. DC_Disc-IUS082311 1 / 4 Additional Information for Installation SMA DC-Disconnect Accessories for PV Inverters Version: 1.1 Mat. DB-DC-DISCON Please check the Installation Guide delivered with your Sunny Boy. If the Installation Guide version is earlier than 2.1 (for example 1.2 or 1.3), then please read this information carefully and follow the instructions below. If your Sunny Boy Installation Guide has the version 2.1 you may disregard this additional information. The SMA DC-Disconnect is a DC circuit breaker disconnecting the PV generator from the inverter. The SMA DC-Disconnect is NOT an AC circuit breaker. This Additional Information describes the wiring of the DC-Disconnect. This instruction does NOT replace the Sunny Boy Installation Guide. Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. The Installation Guide describes how to connect the DCDisconnect and provides information on the torque of the cable connection. AC Wiring with SMA DC-Disconnect The Sunny Boy 3000US and 4000US are suitable for the connection to a 208 V and 240 V grid. The Sunny Boy 5000US, 6000US and 7000US are suitable for the connection to a 208 V, 240 V and 277 V grid. L1 Connect the black L1 (AC line 1 or UNGROUNDED) wire to the terminal labeled L1 in the SMA DC-Disconnect L2 Connect the red L2 (AC line 2) to the terminal labeled L2 in the SMA DC-Disconnect. Only for 277 V: L2 terminal not used! N Connect the white N (AC line N) wire to the terminal labeled N in the SMA DCDisconnect. PE Connect the green-yellow AC equipment- ground wire to the PE terminal labeled in the SMA DC-Disconnect. SMA Solar Technology AG DC_Disc-IUS082311 2 / 4 Additional Information for Installation DC Ground Wiring With SMA DC-Disconnect Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. DC Wiring With SMA DC-Disconnect Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. A Connect the grounding electrode conductor with the grounding electrode. B Connect the PV generator grounding to the grounding electrode. Negative Grounding Connect the positive DC wires to the terminal labeled PV UNGROUNDED in the SMA DC-Disconnect. Connect the negative DC wires to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Positive Grounding Connect the negative DC wires to the terminal labeled PV UNGROUNDED in the SMA DC-Disconnect. Connect the positive DC wires to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. SMA Solar Technology AG DC_Disc-IUS082311 3 / 4 Additional Information for Installation DC Wiring With Additional DC Distribution When combining strings outside of the SMA DC-Disconnect, and when the combined input of a single source circuit is greater than 15 A, use the terminal labeled COMBINED for the ungrounded conductor. DO NOT use the terminals 1 – 4 labeled UNGROUNDED in this case. For connecting the DC wires to the Sunny Boy, see Installation Guide of the Sunny Boy. Torque Values and Wire Sizes SMA DC-Disconnect Additional DC Source Circuit Note: This circuit will no longer be fused so additional DC source circuit fusing may be required in order to meet UL and NEC. Negative Grounding Connect the positive DC wire to the terminal labeled COMBINED in the SMA DC-Disconnect. Connect the negative DC wire to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Positive Grounding Connect the negative DC wire to the terminal labeled COMBINED in the SMA DC-Disconnect. Connect the positive DC wire to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Wire Size AC & DC Terminal Blocks 15 1.7 6 – 10 AWG Combined Terminal Block Spring Terminal Spring Terminal 6 – 10 AWG Grounding Electrode Conductor Block 15 1.7 6 – 10 AWG SMA Solar Technology AG DC_Disc-IUS082311 4 / 4 Additional Information for Installation AC Wiring in the Sunny Boy Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. L1 Connect the black L1 (AC line 1 or UNGROUNDED) wire of the SMA DCDisconnect to the terminal labeled L1 in the Sunny Boy. L2 Connect the red L2 (AC line 2) wire of the SMA DC-Disconnect to the terminal labeled L2 in the Sunny Boy. N Connect the white N (AC line N) wire of the SMA DC-Disconnect to the terminal labeled N in the Sunny Boy. PE Connect the green-yellow AC equipment-ground wire of the SMA DCDisconnect to the PE terminal labeled in the Sunny Boy. WE WILL USE ADDRESS ON FILE AT THE TIME OF CHECKOUT AND WILL NOT ACCEPT RESPONSIBILITY FOR ADDRESSES THAT ARE INCORRECT OR UNDELIVERABLE. PLEASE PAY FOR ITEMS WITHIN 7 DAYS OF ITEM CLOSING DATE. We are located 30 minutes from. Pay with Pay Pal. The item “8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter” is in sale since Thursday, February 23, 2017. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “dualsportgirl” and is located in Nevada City, California. This item can be shipped to United States, to Canada, DK, RO, SK, BG, CZ, FI, HU, LV, LT, EE, to Australia, GR, SI, KR, ID, to Taiwan, ZA, TH, to France, to Hong Kong, to Germany, to Austria, to Mexico, SG, HR, MY, BR, CL, CO, CR, PA, TT, GT, HN, JM.
  • Brand: SMA
  • MPN: Does Not Apply
  • Country/Region of Manufacture: Germany

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
Category: count | Comments Off
January 2

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
New, unopened, factory sealed box. You will receive 8 count SMA DC Disconnect/Combiner Boxes in this offer. DC_Disc-IUS082311 1 / 4 Additional Information for Installation SMA DC-Disconnect Accessories for PV Inverters Version: 1.1 Mat. DB-DC-DISCON Please check the Installation Guide delivered with your Sunny Boy. If the Installation Guide version is earlier than 2.1 (for example 1.2 or 1.3), then please read this information carefully and follow the instructions below. If your Sunny Boy Installation Guide has the version 2.1 you may disregard this additional information. The SMA DC-Disconnect is a DC circuit breaker disconnecting the PV generator from the inverter. The SMA DC-Disconnect is NOT an AC circuit breaker. This Additional Information describes the wiring of the DC-Disconnect. This instruction does NOT replace the Sunny Boy Installation Guide. Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. The Installation Guide describes how to connect the DCDisconnect and provides information on the torque of the cable connection. AC Wiring with SMA DC-Disconnect The Sunny Boy 3000US and 4000US are suitable for the connection to a 208 V and 240 V grid. The Sunny Boy 5000US, 6000US and 7000US are suitable for the connection to a 208 V, 240 V and 277 V grid. L1 Connect the black L1 (AC line 1 or UNGROUNDED) wire to the terminal labeled L1 in the SMA DC-Disconnect L2 Connect the red L2 (AC line 2) to the terminal labeled L2 in the SMA DC-Disconnect. Only for 277 V: L2 terminal not used! N Connect the white N (AC line N) wire to the terminal labeled N in the SMA DCDisconnect. PE Connect the green-yellow AC equipment- ground wire to the PE terminal labeled in the SMA DC-Disconnect. SMA Solar Technology AG DC_Disc-IUS082311 2 / 4 Additional Information for Installation DC Ground Wiring With SMA DC-Disconnect Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. DC Wiring With SMA DC-Disconnect Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. A Connect the grounding electrode conductor with the grounding electrode. B Connect the PV generator grounding to the grounding electrode. Negative Grounding Connect the positive DC wires to the terminal labeled PV UNGROUNDED in the SMA DC-Disconnect. Connect the negative DC wires to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Positive Grounding Connect the negative DC wires to the terminal labeled PV UNGROUNDED in the SMA DC-Disconnect. Connect the positive DC wires to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. SMA Solar Technology AG DC_Disc-IUS082311 3 / 4 Additional Information for Installation DC Wiring With Additional DC Distribution When combining strings outside of the SMA DC-Disconnect, and when the combined input of a single source circuit is greater than 15 A, use the terminal labeled COMBINED for the ungrounded conductor. DO NOT use the terminals 1 – 4 labeled UNGROUNDED in this case. For connecting the DC wires to the Sunny Boy, see Installation Guide of the Sunny Boy. Torque Values and Wire Sizes SMA DC-Disconnect Additional DC Source Circuit Note: This circuit will no longer be fused so additional DC source circuit fusing may be required in order to meet UL and NEC. Negative Grounding Connect the positive DC wire to the terminal labeled COMBINED in the SMA DC-Disconnect. Connect the negative DC wire to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Positive Grounding Connect the negative DC wire to the terminal labeled COMBINED in the SMA DC-Disconnect. Connect the positive DC wire to the terminal labeled PV GROUNDED in the SMA DC-Disconnect. Wire Size AC & DC Terminal Blocks 15 1.7 6 – 10 AWG Combined Terminal Block Spring Terminal Spring Terminal 6 – 10 AWG Grounding Electrode Conductor Block 15 1.7 6 – 10 AWG SMA Solar Technology AG DC_Disc-IUS082311 4 / 4 Additional Information for Installation AC Wiring in the Sunny Boy Pay attention to all operation and safety instructions listed in the Installation Guide of the Sunny Boy. L1 Connect the black L1 (AC line 1 or UNGROUNDED) wire of the SMA DCDisconnect to the terminal labeled L1 in the Sunny Boy. L2 Connect the red L2 (AC line 2) wire of the SMA DC-Disconnect to the terminal labeled L2 in the Sunny Boy. N Connect the white N (AC line N) wire of the SMA DC-Disconnect to the terminal labeled N in the Sunny Boy. PE Connect the green-yellow AC equipment-ground wire of the SMA DCDisconnect to the PE terminal labeled in the Sunny Boy. WE WILL USE ADDRESS ON FILE AT THE TIME OF CHECKOUT AND WILL NOT ACCEPT RESPONSIBILITY FOR ADDRESSES THAT ARE INCORRECT OR UNDELIVERABLE. PLEASE PAY FOR ITEMS WITHIN 7 DAYS OF ITEM CLOSING DATE. We are located 30 minutes from. Pay with Pay Pal. The item “8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter” is in sale since Monday, January 02, 2017. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “dualsportgirl” and is located in Nevada City, California. This item can be shipped to United States, to Canada, DK, RO, SK, BG, CZ, FI, HU, LV, LT, EE, to Australia, GR, SI, KR, ID, to Taiwan, ZA, TH, to France, to Hong Kong, to Germany, to Austria, to Mexico, SG, HR, MY, BR, CL, CO, CR, PA, TT, GT, HN, JM.
  • Brand: SMA
  • MPN: Does Not Apply
  • Country/Region of Manufacture: Germany

8 count SMA DC Disconnect and Combiner Box for Solar Electric Grid Tie Inverter
Category: count | Comments Off
April 30

Schneider Electric TX2800 Grid Tie Inverter

Schneider Electric TX2800 Grid Tie Inverter
Schneider Electric TX2800 Grid Tie Inverter

Schneider Electric TX2800 Grid Tie Inverter
Removed due to upgrade. The TX Grid-tie Solar Inverter from Schneider Electric (Formerly Xantrex). Schneider Electric’s TX single phase inverters offer a simple and flexible solar grid-tie solution for small commercial and residential applications. This range of TX inverters uses a proven high-frequency design in a compact enclosure. Conext inverters use Schneider Electrics FastSweep technology–an innovative maximum power point tracking (MPPT) feature that ensures increased energy harvest in shaded conditions. These inverters contain an integrated dc and ac disconnect switch and are optimized for common service panel breaker sizes. The products are easily installed as a single inverter for a single photovoltaic (PV) array, or in a multiple-inverter configuration for larger grid-tie systems. An NEC compliant, integrated Square DTM DC/AC disconnect, standard in the GT Series, eliminates the need for external DC (PV) disconnects, and in some jurisdictions, AC disconnects. Shade tolerant Fast Sweep MPPT technology. Large heat-sink offers extraordinary heat dispersion without the need for a cooling fan Large wiring enclosure. 240 / 208 V operation; works out of the box for single phase residential and three phase commercial applications. Lightweight and easy to install. Inverters can be mounted side by side with zero clearance. LCD provides instantaneous information power level, daily energy and lifetime production, system status, and installer customized screens. Sealed inverter enclosure can be quickly separated from the wiring box allowing DC/AC connections to remain intact in the event the inverter needs to be serviced. The item “Schneider Electric TX2800 Grid Tie Inverter” is in sale since Saturday, April 30, 2016. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “invertersystems” and is located in Northfield, Vermont. This item can be shipped to United States.
  • Brand: Xantrex/Schneider
  • Model: TX2800
  • Type: Grid Tie Inverter

Schneider Electric TX2800 Grid Tie Inverter
Category: schneider | Comments Off