August
20
2400w grid tie solar power inverter dc10.5-30V or 22-50v CABLE 1200w2pcs
NEW design 1200w grid tie solar power inverter dc10.5-30V or 22-50v and CABLE AC 110V OR 220V. This manual contains important instructions to follow during installation and maintenance of the Microinverter. To reduce the risk of electrical shock, and to ensure the safe installation and operation of the Microinverter, the following safety symbols appear throughout this document to indicate dangerous conditions and important safety instructions. This indicates a situation where failure to follow instructions may be a safety hazard or cause equipment malfunction. Use extreme caution and follow instructions carefully. If not follow instruction may be burned. Be aware that the body of the Microinverters is the heat sink and can reach a temperature of 80. To reduce risk of burns, do not touch. Please install the inverter where children can not reach to reduce risk of shock and burns. Minors and mental patients. Prohibition use of this products. Perform all electrical installations in accordance with all local electrical codes. Be aware that only qualified personnel should install and/or replace Microinverters. Connect the Microinverter to the electrical utility grid only after receiving prior approval from the utility company. And only qualified electrical engineer can perform the operation. Non-professionals do not disassemble or repair the inverter. Before installing or using the Microinverter, please read all instructions and cautionary markings in the technical description and on the Microinverter system and the PV-array. Please install the inverter in ventilated place and away from flammable materials. Do NOT disconnect the PV module from the Microinverter before removing AC power. The inverter transform solar photovoltaic (PV) DC power into AC power and fed into the power grid. Maximum DC input voltage. One way maximum input current. Maximum units per branch. Permission Max-current per branch. Natural convection – No fans. Reverse transfer, load priority. DIN VDE 1026 UL1741. Check the product and the parts if complete, the list as below. Product or parts name. Check the installation Ambient if as requested. Local ambient temperature is -20. Easy corrosive gas or liquid nearby. Not be installed in easily flooded or snow-covered areas. Not be installed in an enclosed or non-ventilated place. Prohibition install it near flammable materials. Not be installed in direct sunlight. Install the Microinverter in the place where children can not touch. Solar panel if as requested. Recommend to use 60cells or 72cells solar panel. The Voc must be in the range of the inverters operation voltage range. If you use 36cells solar panel, you can connect 2pcs in series then connect to Micoinverter, and the total power cant over 350W. There have 4 input ports of the 1200W. We recommend to use 4pcs of solar panel to connect with the Microinverte. 1200W input port use standard MC4 connector, please check if there have MC4 connector of solar panel. Confirm the voltage and frequency of the 1200W which you ordered is match with your local utility grid. Except bracket, solar panel, inverter and other related parts, you also need the below tools and parts. Prohibition to connect the 1200W Microinverter to utility grid if do not install the inverter following the below steps. Please determine the installation site refer to 3.1.2. Make sure the inverter and bracket grounding, otherwise install a dedicated line for the inverter of grounding. Use the AC cable to connect the neighboring Maysun1200W Microinverters, and the end terminal of cable connect to the AC box. Before connect the AC box, make sure do not connect to utility grid. If the AC output voltage in the range of 200-250V, the maximum is 5pcs Maysun1200W Microinverters for each branch; if the AC output voltage in the range of 100-130V, the maximum is 3pcs Maysun1200w Microinverters for each branch; the maximum current is 30A for e. Select the right earth leakage protection switch and breaker according to the system maximum current. Covered the solar panel with opaque object, then connect the Maysun1200W Microinverter with the 4pcs of solar panel. 1200W have 4 DC input ports, each input port can connect maximum 350W(20A), over power or over current will damage the 1200W. Check all the terminal in right and stable connected , then connect to utility grid and remove the opaque object on the solar panel. Check the LED on the Maysun1200W, if the LED in green, congratulations, you complete finish the installation. DC power supply the LED. If the DC voltage around 10.5V, the LED will light up. MPPT is been tracking. DC voltage if low. Utility grid power off or the utility voltage is not match the Microinverter. Short circuit of AC terminal. Input voltage or current not stable, pls check if there have enough current from the solar panel. Steps for replace fault Microinverter. Use opaque object to cover the solar panels which connect to the fault Microinverter. Disconnect the fault Microinverter and utility grid. Disconnect the fault Microinverter and AC cable. Disconnect the fault Microinverter and solar panel. Remove the fault Microinverter from the bracket. Fix the new Microinverter to the bracket. Connect the new Microinverter to the AC cable. Connect the new Microinverter to the solar panel. Connect the new Microinverter to the utility grid. Remove the opaque object on the solar panel. Your praise is very important to us. So when you received goods and satisfied with our goods please give our good feedback. If you have any question, please immediately inform us. We will together with you to solve as soon as possible. I hope that every time we communicate happily. If you are not satisfied our items or our item demage. Inverter were used or damaged or deformed or altered in any ways are not acceptable. The item “2400w grid tie solar power inverter dc10.5-30V or 22-50v CABLE 1200w2pcs” is in sale since Saturday, August 20, 2016. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “luckpower2012″ and is located in fj. This item can be shipped to United States.
- Brand: oem
- Model: wvc1200
- MPN: Does Not Apply
- Country/Region of Manufacture: China