February 26

(BOX OF 12) Enphase M215-IG Grid Tie Micro Inverter M215-60-2LL-S22-IG

(BOX OF 12) Enphase M215-IG Grid Tie Micro Inverter M215-60-2LL-S22-IG
(BOX OF 12) Enphase M215-IG Grid Tie Micro Inverter M215-60-2LL-S22-IG
(BOX OF 12) Enphase M215-IG Grid Tie Micro Inverter M215-60-2LL-S22-IG
(BOX OF 12) Enphase M215-IG Grid Tie Micro Inverter M215-60-2LL-S22-IG

(BOX OF 12) Enphase M215-IG Grid Tie Micro Inverter M215-60-2LL-S22-IG
These are new M215 Enphase inverters. These are the New IG style inverter with integrated ground (requires no additional grounding wire) and are equipped. These can be used along with the newer M250 or older versions of M215 inverters. These inverters attach to the standard Enphase Engage cabling system (the same cable used with the M250). The M215 micro-inverter can be used with 60 cell panels with a MPPT Voltage range of 27-39 VDC (see recommended input power below). The M215 auto-detects if the grid is 240VAC (211-264VAC) or 208VAC (183-229VAC) 3-phase. The M215 has MC4 connectors that connect to your MC4 solar panel connectors. Each 240VAC branch circuit can have 17 micro-inverters maximum (17 modules). Each 208VAC branch circuit can have 25 micro-inverters maximum (25 modules). You may have multiple branch circuits. Enphase Engage AC cable system is used with cable drops to quickly connect each inverter along the AC trunk. Each branch circuit requires a 20 amp breaker. Branch circuits can be combined together with a load center. One Enphase end termination cap is needed at the end of the Engage AC branch circuit cabling. The Enphase Energy Microinverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. Works with the Envoy Communications Gateway monitoring system just like the M250. Resilient to dust, debris, and shading. Performance monitoring per module. System availability greater than 99.8%. No single point of system failure. Quick & simple design, installation and management. Works with 60 Cell Modules (see recommended power below). The M215 has (1) set of DC inputs. Recommended Input Power (STC). Maximum Input DC Voltage. Peak Power Tracking Voltage. 27 volts DC to 39 volts DC. 16 Volts DC /48 Volts DC. Output Data (208 AC). 208 Volts / 183 Volts to 229 Volts. 208 Volts / 179 Volts to 232 Volts. 60.0 / 57-61 Hz. Maximum units per 20A branch: 25. Output Data (240 AC). Maximum Output Power: 225 Watts. Nominal Voltage/Range: 240 Volts / 211 Volts to 264 Volts. Extended Voltage/Range: 240 Volts / 206 Volts to 269 Volts. Nominal Frequency/Range: 60.0 /. Extended Frequency/Range: 60.0 /. Power Factor: >0.95. Maximum units per 20A branch: 17. Nominal MPP Tracking: 99.4%. Operating Temperature Range: -40°C to 65°C. Night time power consumption. 171 mm x 173 mm x 30 mm (without mounting bracket). 1.6 kg (3.4 lbs). Cooling: Natural Convection – No fans. Compliance UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0.4-04, and 107.1-01. Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in. Equipment ground is provided in the Engage Cable. Additional GEC or ground is required. Ground fault protection (GFP) is. Integrated into the microinverter. Frequency ranges can be extended beyond nominal if required by the utility. The item “(BOX OF 12) Enphase M215-IG Grid Tie Micro Inverter M215-60-2LL-S22-IG” is in sale since Monday, January 22, 2018. This item is in the category “Home & Garden\Home Improvement\Electrical & Solar\Alternative & Solar Energy\Chargers & Inverters”. The seller is “sepacenergy” and is located in Rancho Cordova, California. This item can be shipped to United States.
  • Brand: Enphase
  • Model: M215-60-2LL-S22-IG
  • Country/Region of Manufacture: China
  • Bundle Listing: Yes

(BOX OF 12) Enphase M215-IG Grid Tie Micro Inverter M215-60-2LL-S22-IG

Tags: , , , , ,

Posted February 26, 2018 by admin in category enphase